Program
of The 10th International Conference on
Magnetic Applications in Dentistry
March7 - March 25, 2011
|
|
|
Chair: Masatake Akutagawa
(The University of Tokushima)
|
|
|
#1
Laser welding between the magnetic stainless steels and titanium as a
shield-ring and spacer material
|
|
Yukyo Takada, M. Takahashi, Jun Shiroto,
A. Kikuchi1 and M. Kikuchi
|
Division
of Dental Biomaterials, Tohoku University Graduate School of Dentistry
1NEOMAX ENGINEERING
Co.,Ltd., Takasaki, Japan
|
|
|
|
|
|
|
#2
Questionnaire Survey for Formulating Clinical Practice Guidelines for
Magnetic Attachments Applications -
Analysis and Selection of the Clinical Questions (CQ) –
|
|
M.Hideshima, Y. Igarashi, T.Ichikawa,
J.Tanaka, T.Kochi, T.Ishigami, T.Andoh*, A.Nishiyama**
|
Dental
Care Council, the Japanese Society of Magnetic Applications in Dentistry,
Section of Removable Prosthodontics,
*
Temporomandibular Joint and Occlusion,
**Graduate
School of Medical and Dental Sciences, Tokyo Medical and Dental University
|
|
|
|
|
|
|
#3
Retentive force and Magnetic flux leakage of new magnetic attachment
|
|
Chihiro Nagoya*,Yoshitada Umekawa*,**,Tomohiko Ishigami*,** ,Osamu
Kujirai***,
Hitoshi Toyoma*,**Masaaki
Takamura*,Masuko Tsuyumu*,Shigeki Endo*
|
*Department
of Partial Denture Prosthodontics, Nihon
University School of Dentistry
**Division
of Clinical Research, Dental Research Center, Nihon University School of Dentistry
***GC Corporation
|
|
|
|
|
|
Chair: Tetsuo Ohyama (Nihon
University School of Dentistry)
|
|
|
|
#4
Attractive Force Analysis of Implant Magnetic Keeper using
Three-Dimensional Finite Element Method
- The effect of surface screw hole
pattern design for magnetic attachments -
|
|
H.
Kumano, T. Masuda, Y. Nakamura, R. Kanbara, T.
Iwai, Y. Ohno, K. Yoshihara, Y.Tanaka
|
Department
of Removable Prosthodontics, School of Dentistry,
Aichi-gakuin University
|
|
|
|
|
|
#5
Introduction of Nonlinear Property into Three-Dimensional Finite Element
Method
– Part 2 Mechanical
Examination of R.P.D. with Extracoronal
Attachment –
|
|
R. Kanbara, Y. Nakamura, Y.
Ohno, T. Iwai, K. Yoshihara, H. Kumano, T. Masuda, Y. Tanaka
|
Department of
Removable Proshodontics, School of Dentistry
Aichi-Gakuin University
|
|
|
|
#6
Examination
of the sensor placement in the swallowing mensuration using Magneto-Impedance sensor
|
|
K. Hamaguchi 1 , M. Akutagawa 2, Y. Tegawa
3, T. Ichikawa 3, Y. Kinouchi
2
|
1Graduate School of Advanced Technology and Science, The Univ.
of Tokushima
2Institute of Technology and Science ,The Univ. of Tokushima
3Institute of Health Biosciences ,The Univ. of Tokushima
|
|
|
|
|
#7
The
Influence of the Screw Hole on the Implant Magnetic Keeper Attachment
Surface
|
|
T.
Iwai, H. Kumano, Y. Nakamura, K. Shoji, T. Masuda, R. Kanbara,
T. Miyata, Y. Ohno, Y. Tanaka
|
Removable Prosthodontics, School of Dentistry, Aichi-Gakuin University
|
|
|
|
|
|
|
Chair: Yukyo Takada ( Tohoku
University )
|
|
#8
Influence of Re-casting on the
Attractive Force of Attract P®
|
|
K.Yoshihara, T.Iwai,
Y.Nakamura, K.Shoji, Y.Ohno, R.Kanbara, T.Masuda, Y.Tanaka
|
Department
of Removable Prosthodontics, School of Dentistry,
Aichi-Gakuin University
|
|
|
|
|
|
|
#9
Retentive
Force and Magnetic Flux Leakage of Magnetic Attachment in Keeper and Castable Magnetic Alloy
|
|
K. Miyata1,M. Hasegawa1,Y. Abe1,T. Azuhata1,H. Saito1,M. Morokuma1,D. Akita1,
T.
Ishigami1,2
|
1Department
of Partial Denture Prosthodontics,Nihon University School of
Dentistry, Japan
2Division of Clinical
Research, Dental Research Center, Nihon University School of Dentistry
|
|
|
|
|
|
|
#10
Theoretical study of MRI metal artifacts
by dental alloy
- Three
dimensional analyses -
|
H.Samejima1, Y.
Tegawa2, Y. Kinouchi3, and M. Akutagawa3
|
1
Graduate
School of Advanced Technology and Science, The University of Tokushima,
2 Institute of
Health Sciences, Graduate School, The University of Tokushima,
3 Institute of
Technology and Science, Graduate School, The University of Tokushima
|
|
|
|
#11
The Effect Different Keeper Tray Materials
Burn-out Incineration on Casting Investment during Burn-out Procedures.
|
|
T.Kogiso, Y.Nakamura,
Y.Ono, R.Kanbara, K,Syoji, T,Masuda, K.Yoshihara, Y.Tanaka
|
Removable Prosthodontics, School of
Dentistry, Aichi-Gakuin University
|
|
|
|
Chair: Masayuki Hideshima ( Tokyo Medical and Dental
University )
|
|
|
|
#12
Retentive force of magnetic attachments
applied to the proximal surface–Part 2–
|
|
Y.
Miyama, Y. Mizuno, D. Okano*1, F. Tsuchida*1,
Y. Takayama*1, N. Takishin*1,
M. Abe*1, C. Ohkubo*1 and T. Hosoi*2
|
Dental
Technician Training Institute, Tsurumi
University School
of Dental Medicine
*1
Department of Removable Prosthodontics, Tsurumi University School
of Dental Medicine
*2
Tsurumi University
|
|
|
|
|
|
|
#13
How
to brush an attachment?
Oral hygiene instructions to attachment
denture patients for dental hygienists
|
|
T. Masuda, Y. Sakakibara
1,M. Kishimoto1, K. Matsushita1, M. Yamaguchi1,
K. Shyoji, R. Kanbara,
Y. Nakamura and Y. Tanaka
|
Department of
Removable Proshodontics, School of Dentistry Aichi-Gakuin University
1Dental Hygienist Section, School of
Dentistry Aichi-Gakuin University Hospital
|
|
|
|
|
|
|
#14
Effect
of Placement of Magnetic Attachment on Retentive Force of Overdenture
|
|
Y. Umekawa1,2,
Y. Ogawa1, K. Ohtani1,2, S. Ohno1,
T. Ishigami1,2.
|
1Department of Partial Denture Prosthodontics, Nihon University
School of Dentistry
2Division
of Clinical Research, Dental
Research Center,
Nihon University School
of Dentistry
|
|
|
|
#15
Effect of
Magnetic Fields on Osteoblasts and Fibroblasts in
vitro
|
|
Fukuzawa R.*, Ozawa S.*,
Maeda H.**, Kubo K.**, Sugita Y.**,
Yoshida W.**, Tanaka Y.*
|
*Department of Removable Prosthodontics, School of Dentistry,
Aichi-Gakuin
University
**Department of Oral Pathology, School of Dentistry, Aichi-Gakuin University
|
|
|
|
Chair: Tatsuhiko Masuda (
Aichi Gakuin University )
|
|
|
|
#16
Longitudinal Study of Magnetic attachments
–Investigation of Probing Depth on Abutment
teeth Part.3-
|
|
Rui Ito, Mamoru Miwata,
Rui Ito, Kazumoto Hoshiai, Yoshinobu Tanaka, Tomohiko Ishigami1), Kanji Ishibasi2),
Eiichi Bando3), Hideki Sasaki4), Hiroshi Mizutani5)
and Toshio Hosoi6)
|
Department of Removable Prosthodontics , School of Dentistry, Aichi-Gakuin University
1Department of Partial Denture Prosthodontics , Nihon University School of Dentistry
2Department of Fixed Prosthodontics , School of Dentistry , Iwate Medical
University
3Department of Fixed Prosthodontics , Institute of Health Biosciences
Graduate School The University of Tokushima
4Sasaki Dental clinic
5Section of Removable Proshodontics Graduate School, Tokyo Medical and Dental
University
6Department of Removable prosthodontics, Turumi
University School of Dental Medicine
|
|
|
|
|
|
|
#17
Longitudinal
Study of Magnetic attachments
―investigation of probing depth on abutment teeth part2 ―
|
|
Miwata.M , Ito.R , Hoshiai.K , Tanaka.Y ,
Ishigami.T1,Ishibasi.K2 , Bando.E3 ,
Sasaki.H4, Mizutani.H5 and Hosoi.T6
|
Department
of Removable Prosthodontics , School of Dentistry,
Aichi-Gakuin University
1Department of
Partial Denture Prosthodontics , Nihon University
School of Dentistry ,
2Department of
Fixed Prosthodontics , School of Dentistry ,Iwate
Medical University ,
3Department of
Fixed Prosthodontics , Institute of Health
Biosciences Graduate School The University of Tokushima ,
4Sasaki Dental
clinic
5Section of
Removable Prosthodontics Graduate School, Tokyo
medical and Dental University
6Department of
Removable Prosthodontics,
Tsurumi University School of Dental Medicine
|
|
|
|
#18
The Effect of the Angle of Axial Surface of
Root Cap upon the Abutment Tooth During Simulated Incisal
Clenching
–The
Boundary Condition of Considering Human Mandible Movement
|
|
Daisuke Yamanaka*, Tetsuo Ohyama
*,**, Shinya Nakabayashi*, Yuusuke
Katakura *, Tendo Uchida*,
Naoki Tsukimura*,**, Tomohiko
Ishigami*,**
|
*Department of Partial Denture Prosthodontics, Nihon University
School of Dentistry
**Division of Clinical Research,
Dental Research Center, Nihon University School of Dentistry
|
|
|
|
#19
Survey of Dental Magnetic Attachments by Quality
Function Deployment Method
|
|
T.
Sigemori , T. Yokoyama, N. Kimura, K. Hoshiai, T. Kawaguchi, R.Ito,
K. Watanabe, M.Miwata, H. Kajiura,
R.Tanaka, Y.Tanaka, T.Hamano✽, H.Nakashima✽
|
Department
of Removable Prosthodontics, School of Dentistry,Aichi-Gakuin
University
*GC Dental Products
|
|
|