Program of The 14th International Conference on
Magnetic Applications in Dentistry
March2 - March 20, 2015
Chair: Yoshinori Nakamura (Aichi Gakuin University)
#1
A case of lower removable partial denture
with intracoronal and extracoronal dental magnetic attachments
Shogo Tsuda, Shin-ichi Masumi, Eri
Makihara, Toshihiro Kawano,
Mayumi Yagi and Masahiro Arita
Division of Occlusion &
Maxillofacial Reconstruction, Department of Oral Function,
Kyushu Dental University
#2
Immediately loaded mandibular 2-implant overdentures retained by magnetic attachments:
Marginal bone loss and survival rate
○Kaidiliya Yalikun, Miyayasu Anna, Kanazawa Manabu, Omura Yuri, Minakuchi Shunsuke
Gerodontology and Oral Rehabilitation, Graduate school, Tokyo Medical and Dental University
#3
A case report of a
removable denture using magnetic attachments for a missing mandibular molar with
a decreased occlusal vertical dimension
followed up for 3 years
M. Sone
Division of Removable Prosthodontics, Department of Restorative and
Biomaterials Sciences, Meikai University School of Dentistry
Chair: Masayuki Hideshima (Tokyo Medical and Dental University)
#4
Denture base strength influence of its thickness surrounding magnetic assembly
-Examination by the model experiments-
T. Kanazawa1, Y. Umekawa1,2, T.
Ishii1, A. Tateno1
E. Nagai1,2, K. Ohtani1,2, K.
Suda1 and T. Ishigami1,2
1Department
of Partial Denture Prosthodontics, Nihon University School of Dentistry
2Division
of Clinical Research, Dental Research Center, Nihon University School of
Dentistry
#5
The thickness of the resin base needed to the top of copings
-Examination by the three-dimensional finite element method-
M. Obayashi1, T. Ohyama1,2, S.
Nakabayashi1,2
S. Tadokoro1, N. Shibuya1, H.
Yasuda1, T. Okubo1 and T. Ishigami1,2
2Division
of Clinical Research, Dental Research Center, Nihon University School of
Dentistry
#6
Fixation of modified magnet assembly to denture base using alternative
resins.
S.
Okayama, H. Shimpo, Y. Suzuki, C. Ohkubo
Department of Removable Prosthodontics, Tsurumi University School of Dental
Medicine
Chair: Tetsuo Ohyama (Nihon University)
#7
Retentive forces and displacement of new stress breaking magnet attachment
Mana Torii, Takuya Waki, Daisuke Ozawa, Yasunori Suzuki,
Chikahiro Ohkubo
Dept. of Removable Prosthodontics, Tsurumi Univ. Sch. of Dent. Med.
#8
Investigation of an optimal magnetic attachment structure using
three-dimensional finite element method
-An
influence of different magnetic assembly and keeper structure on attractive
force-
H Nagai .1, H Kumano. 1, R
Kanbara. 1,A Andou. 1, K Tuda. 1, T Iwata.
1,
Y Nakamura. 1, Y Takada.2 and Y
Tanaka1.
1Department
of Removable Prosthodontics, School of Dentistry, Aichi-Gakuin University
2Division
of Dental Biomaterials, Tohoku University Graduate School of Dentistry
#9
The
Relining Method of Removable Denture with Magnetic Attachments
A. Hiraoka1, T. Masuda1, T.
Tanaka2, K. Hayashi1, K. Shiraishi1, R. Kanbara1,
Y. Nakamura1, F. Ito2, M. Okada2 and Y. Tanaka1
1Department
of Removable Prosthodontics, School of Dentistry, Aichi-Gakuin University
2Dental
Laboratory of University Hospital, Aichi-Gakuin University