[JSMAD Home] [Program] [Abstract]

Paper ID S003 : Clinical evaluation of implant overdentures using magnetic attachment: retrospective study


Posted Messages (Last post: Tue Mar  9 18:49:53 2021)
[0001] [0002] 
[Go to Form]

[0001]
尾澤 昌悟 moderator (Aichi gakuin Univ )

It should be precious to present excellent results of IOD using magnetic attachments. Magnet denture provides esthetic and functional rehabilitation for edentulous patients or patients who had limited number of remaining teeth. I would like to know how many attachments did you use per patient. And how much total of retentive forces should be appropriate for implant retained magnet denture?

[0002]
Hiroaki Takayama (Department of Removable Prosthodontics,Tsurumi University School of Dental Medicine )

Thank you for your question.
2-4magnetic attachments are used per fully edentulous patients.
For partially edentulous patients, the number of attachments will vary depending on the remaining tooth.

Next, the appropriate retentive forces are 800 to 1000 grams for implant-retained magnetic dentures.

This bulletin board is opened from February 26th, 2021 to March 16th, 2021.